AMI membranes TFC 1812/3012 100, 150, 300 GPD
//www.sinergroup.net/EN/Membranes/AMI+membrane+TFC+1812%2F3012+100%2C+150%2C+300+GPD+%7E2825%7E29/090007-p.htm
AMI Membrane home membrane elements, are among the finest in the industry. With hundreds of thousands of membranes in operation world-wide, we offer these in a large range of both residential and commercial sizes AMI Membranes are Made in the USA in our ISO 9001:2008 Certified Facilities. For the past 30 years AMI Membrane elements have earned the reputation of consistent quality.
Recommended Operating Conditions (50, 75, 100, 150gpd)
* Maximum operating pressure: 125 psi (8, 61bar)
* Maximum feed flow rate: 2 gpm (7, 57lt./min.)
* Maximum operating temperature: 113°F (45°C)
* Maximum feed water turbidity: 1 NTU
* Maximum feed water silt density index (15 min): 5
* Chlorine tolerance: < 0.1 ppm
* Feed water pH range, Continuous Operation: 2-11
* Feed water pH range, Short-Term Cleaning (30 minutes): 1-12
* Minimum brine flow to permeate flow ratio: 4:1
* Dimensions: 50, 75, 100gpd L-11, 75"(29, 85cm) I-10"(25, 4cm) D-1, 75"(4, 57cm)
* Dimensions: 150gpd L-11, 75"(29, 85cm) I-10"(25, 4cm) D-1, 95"(5cm)
Note: Salt rejection and performance specifications shown are from internal test data.
Performance specifications based on 500 ppm tap water, 50 psi (3, 44bar) applied pressure, 77°F (25°C) feed water temperature, feed water pH 7-8 and 15% recovery. Element permeate flow may vary ± 20%.
The 150 gpd membranes are designed for a tight fit in most standard housings. If the membrane fits loosely, you may need to wrap a few layers of tape near one end to make a tight fit.
Recommended Operating Conditions (300gpd)
* Maximum operating pressure: 300 psi (20, 68bar)
* Maximum feed flow rate: 6 gpm (22, 71lt./min.)
* Maximum operating temperature: 113°F (45°C)
* Maximum feed water turbidity: 1 NTU
* Maximum feed water silt density index (15 min): 4
* Chlorine tolerance: < 0.1 ppm
* Feed water pH range, Continuous Operation: 2-11
* Feed water pH range, Short-Term Cleaning (30 minutes): 1-12
* Single Element recovery: 15%
* Dimensions: 300gpd A-11, 75"(29, 85cm) B-10, 25"(26, 03cm) C-3"(7, 61cm) E-3, 2"(8, 12cm)
Note: Note: Performance specifications based on, Tap Water, 77°F (25°C) feed water temperature, pH 8 and 10% recovery. Element permeate flow may vary ± 15%.
* We provide only businesses companies such as distributors, retailers, manufacturers and assemblers.